Industries
Where BRISOL runs.
Six industries around Coimbatore and Tirupur account for most of our installs. The failure modes differ; the fix is usually the same: dry the air before it reaches the tool.
Textile mills
ProblemWater in loom and ring-frame pneumatics; rust on cylinder rods; fabric staining from oil carry-over.
FixMicro filter after the aftercooler, auto-drain before every FRL.
Auto components
ProblemMoisture in CNC air blast and clamping circuits; spool valves sticking on 3-shift lines.
FixDry air at the header plus point-of-use drains at each machine drop.
Food & beverage
ProblemCondensate in filling and capping air; oil odour in product-contact air.
FixSeparator and filters before the dryer, carbon filter last in line.
Foundry
ProblemDust and heat kill float drains; long pipe runs collect sludge at every low point.
FixHigh-discharge timer drains (no float) at the receiver, cooler and every low point.
Packaging
ProblemWet air on pick-and-place and sealing-bar solenoids; frequent coil replacement.
FixDry air to the header; correctly rated 24 V DC coils on the machines.
Pumps & motors
ProblemTest-rig air must stay dry for pressure-decay and leak tests.
FixFilter and auto-drain at the rig inlet; 3/2 valves for test sequencing.