उद्योग

BRISOL कहाँ चलता है।

Coimbatore और Tirupur के आसपास छह उद्योगों में हमारे अधिकतर installs हैं। समस्याएँ अलग होती हैं; समाधान अक्सर एक ही: tool तक पहुँचने से पहले हवा सुखाइए।

Textile mills

ProblemWater in loom and ring-frame pneumatics; rust on cylinder rods; fabric staining from oil carry-over.
FixMicro filter after the aftercooler, auto-drain before every FRL.

Auto components

ProblemMoisture in CNC air blast and clamping circuits; spool valves sticking on 3-shift lines.
FixDry air at the header plus point-of-use drains at each machine drop.

Food & beverage

ProblemCondensate in filling and capping air; oil odour in product-contact air.
FixSeparator and filters before the dryer, carbon filter last in line.

Foundry

ProblemDust and heat kill float drains; long pipe runs collect sludge at every low point.
FixHigh-discharge timer drains (no float) at the receiver, cooler and every low point.

Packaging

ProblemWet air on pick-and-place and sealing-bar solenoids; frequent coil replacement.
FixDry air to the header; correctly rated 24 V DC coils on the machines.

Pumps & motors

ProblemTest-rig air must stay dry for pressure-decay and leak tests.
FixFilter and auto-drain at the rig inlet; 3/2 valves for test sequencing.